Digital thermostat XK-W1010, -50 to +120°C, 230V power supply

Thermostat with one circuit and double display. The left display shows the actual temperature, the right display the set temperature.
Obrázek
News
Obrázek
Obrázek (1)
Obrázek (2)
Obrázek (3)
18,80 EUR 15,54 EUR excl. VAT
Buy
Poptat
Dočasně nedostupné
Personally in shop:on requestWith a delivery company:on request
CodeDTT 452-2PNX/-50 až 120°C+(SDK)

Thermostat with one circuit and double display. The left display shows the actual temperature, the right display the set temperature. Specifications: Working voltage: 230VAC Output: in active state 230VAC, via relay switching contact 250VAC/5A Temperature measurement range: -50-120°C Resolution: 0.1°C (above 100°C 1°C), accuracy 0, 5°C in the range -10°-100°C Measurement frequency: 2x / sec Measuring sensor: 1x NTC (10kohm 0.5%), waterproof Dimensions: 75×55×30mm Instructions for use: Normal mode: Red LED display on the left shows the temperature in real time, the blue LED panel on the right shows the set temperature. Setting mode: The red LED display on the left shows the setting mode, the blue LED display on the right shows the setting content. How to set the start or end temperature: Press the “SET” button once and the screen will flash. Press the "up" and "down" buttons to set the temperature. Note: The output relay has a voltage of 230V applied to the switching contact, so its output is also 230V in the active state. The red and yellow wires are connected, the black wires are connected via the relay. The product is not an independently functional unit, it requires professional assembly. Working modes: -Heating mode (T1 < T2): After switching on the device, the thermostat output is closed until the measured temperature reaches the T2 level. As soon as the measured value drops to the T1 level, the output is activated again. -Cooling mode (T1 > T2): After switching on the device, the output is inactive until the measured temperature reaches the T1 level. Then the output is activated until the measured temperature reaches the T2 level. Note: The output relay has a supply voltage of 12V supplied to its switching contact, so that its output is in an active state of 12V from the power source. To control 230V appliances, it is therefore necessary to use another relay or modify the circuit board of the thermostat so that the output contacts of the relay are connected separately. i.e. without applied supply voltage. The relay (type 4181) has rated contacts for 230VAC/5A

DescriptionDownload
Tento internetový obchod ukládá soubory cookies, které pomáhají k jeho správnému fungování. Využíváním našich služeb s jejich používáním souhlasíte.
Detailed settingsAllow everything